What is an EICR? Meaning, who needs one and what you get

EICR stands for Electrical Installation Condition Report. It’s a qualified electrician’s inspection and test of a property’s fixed wiring, with a report that says whether the installation is safe to keep using.

By the EICR London Pro team Updated 7 min read

Inside a new consumer unit during installation, with live, neutral and earth conductors dressed to each breaker
A consumer unit upgrade, mid-installation

An EICR is an Electrical Installation Condition Report: a qualified electrician’s inspection and test of a property’s fixed wiring, with a written report on whether it’s safe to keep using. The electrician checks the consumer unit (fuse board), circuits, sockets, switches and lights, tests every circuit, and gives each problem a code. Landlords in England must have one at least every five years.

People call it many things — an electrical safety certificate, a landlord electrical certificate, periodic inspection and testing, or, in business premises, fixed wire testing. They all mean the same check. This guide explains what an EICR is, what it covers, who needs one, and what the report tells you.

EICR at a glance

What you want to knowThe short answer
Full nameElectrical Installation Condition Report
What it isAn inspection and test of an existing fixed electrical installation, and the report of the results
What it checksThe consumer unit, wiring, circuits, sockets, switches, lights and wired-in equipment
Who needs oneLandlords by law (at least every 5 years); businesses to show their electrics are kept safe; homeowners by choice
How long it takesA few hours for a small home; longer for bigger homes and business premises
The resultSatisfactory or unsatisfactory, with every problem coded C1, C2, C3 or FI
How oftenRented homes: at least every 5 years. Owner-occupied homes: every 10 years is recommended

The EICR meaning, word by word

  • Electrical installation — the fixed wiring and everything wired into it: the consumer unit, the circuits, the sockets, switches and light fittings, and fixed equipment such as an electric shower, an oven or an extractor fan. Things you plug in aren’t part of the installation.
  • Condition — the report describes the state of an installation that already exists. It doesn’t certify new work.
  • Report — it’s a record of what the electrician found on the day, with test results and recommendations.

That last point is why an EICR isn’t strictly a certificate, even though most people call it one. Certificates are for new work: an Electrical Installation Certificate (EIC) for a rewire, a new circuit or a new consumer unit, and a Minor Works certificate for small jobs. Our guide to EICR vs EIC vs PAT testing sets out which document you need and when.

What an EICR covers, and what it doesn’t

The inspection has two parts. First the electrician looks: at the consumer unit, the condition of cables and accessories, signs of overheating or damage, and the earthing and bonding — the connections that keep metal parts safe if there’s a fault. Then they test, circuit by circuit: continuity, insulation resistance, polarity, earth fault loop impedance, and the RCDs — the safety switches that cut the power when something goes wrong. Our guide to what an EICR checks explains each test in plain English.

An EICR doesn’t cover:

  • plug-in appliances — that’s PAT testing;
  • gas appliances and boilers — those need a Gas Safe engineer;
  • wiring that can’t be reached without lifting floors or opening walls — the report lists anything not inspected as a limitation, with the reason.

Who needs an EICR?

WhoDo they need one?
Private landlords in EnglandYes, by law. Before a tenancy starts and at least every 5 years, or sooner if the report says so
Social landlordsYes, by law, since 1 December 2025 — the same rules as private landlords
HMO landlordsYes, by law, and councils commonly ask for a current report with a licence application
BusinessesThe law requires electrical systems to be kept safe; an EICR is the usual evidence, and insurers and landlords often ask for one
HomeownersNot required, but recommended every 10 years, when you buy a home, and before a renovation
Buyers and sellersNot a legal requirement for a sale, but the property information form asks whether the home has one

Landlords. The Electrical Safety Standards in the Private Rented Sector and Social Rented Sector (England) Regulations 2020 require the installation in every let home to be inspected and tested by a qualified person. Tenants must get a copy, and any C1 or C2 item, or any further investigation the report asks for, must be dealt with within 28 days, or sooner if the report says so. Our landlord’s guide to EICRs covers every duty, and how long an EICR lasts for a rental property explains the five-year rule with worked dates.

Businesses. The Electricity at Work Regulations 1989 don’t set an inspection date, but they do require systems to be maintained to prevent danger. Regular inspection and testing is how most businesses meet that duty — see EICRs for businesses.

Homeowners. Electrical Safety First recommends an inspection every 10 years for a home you own and live in. It’s also worth having one when you move into an older home, before building work, or if you notice warning signs: scorch marks, a burning smell, sockets that feel warm, or switches that keep tripping. Selling or buying? See do you need an EICR to sell a house?

What happens during an EICR

  1. The electrician agrees the extent of the inspection — normally the whole installation — and notes anything that can’t be reached.
  2. They inspect the consumer unit, the visible wiring, and the sockets, switches and fittings.
  3. They test every circuit. Some tests need the power off, so circuits are switched off for short periods and back on again.
  4. They write up the report, with the overall result, each observation and its code, the test results and the date of the next inspection.

For a typical flat or house this takes a few hours; bigger homes, HMOs and business premises take longer, because there are more circuits to test. You don’t need to be there, as long as someone can let the electrician in. How long an EICR takes and how to prepare for an EICR cover the day itself.

What you get: the report

An EICR follows the model form in BS 7671, the UK wiring regulations (the current form is for BS 7671:2018+A4:2026). The main parts are:

  • The overall assessment — satisfactory or unsatisfactory for continued use.
  • The observations, each with a code:
    • C1 — danger present. Risk of injury. Immediate remedial action is necessary.
    • C2 — potentially dangerous. Urgent remedial action is necessary.
    • C3 — improvement recommended.
    • FI — further investigation is advised.
  • The extent and limitations — what was and wasn’t inspected, and why.
  • The recommended date of the next inspection.
  • The schedules — the checklist of what was inspected, and the test results for every circuit.

On the current forms, only a C1 or C2 makes the report unsatisfactory. EICR codes explained goes through each code, what to do if your EICR is unsatisfactory covers the next steps, and our sample EICR report shows what each section looks like.

How long an EICR lasts

An EICR doesn’t expire like a certificate. It records the installation on the day of the inspection, and the electrician recommends when the next one is due:

  • Rented homes and HMOs — at least every 5 years, or by the earlier date on the report. For a landlord, that date is the legal deadline.
  • Homes you own and live in — every 10 years is recommended.
  • Business premises — industry guidance recommends at least every 5 years for most premises.

Our guides to EICR validity and how often you need an EICR go into the detail.

Who can carry out an EICR

The landlord regulations ask for a qualified person: someone competent to inspect and test an installation to BS 7671. When you compare quotes, ask two questions:

  • Will every circuit be tested? A proper EICR includes test results for each circuit, not just a visual check.
  • Will I get the full schedules? A report without a schedule of test results isn’t a complete EICR.

If a quote looks unusually low, ask whether every circuit will be tested. Our EICR cost guide explains what affects the price, and what to look out for.

What an EICR costs in London

With us, any flat or house with one consumer unit costs £90 inc VAT (£75 + VAT), from a studio to a family house. HMOs, extra fuse boards and business premises are priced on a quick call. Any remedial work is quoted separately, and you’re free to use any qualified electrician. See our EICR prices in London.

Key points

  • EICR stands for Electrical Installation Condition Report.
  • It’s an inspection and test of the fixed wiring — not plug-in appliances, and not gas.
  • Strictly it’s a report, not a certificate, though most people call it an electrical safety certificate.
  • Landlords in England must have one at least every five years; homeowners are advised to have one every ten.
  • The report is satisfactory or unsatisfactory; only C1 and C2 items make it unsatisfactory on the current forms.

Book your EICR in London

We inspect and test every circuit to BS 7671, explain every code in plain English, and email the report as a PDF. Tell us who can let us in and we’ll arrange access with them.

Get your price and book, see our landlord EICR and homeowner EICR services, or call 07500 202010.

FAQ

Quick answers

Is an EICR the same as an electrical safety certificate?
Usually, yes. When people — letting agents included — ask for a "landlord electrical safety certificate" or an "electrical certificate", they normally mean an Electrical Installation Condition Report (EICR). Strictly, an EICR is a report on the condition of an existing installation rather than a certificate. Certificates are issued for new work: an Electrical Installation Certificate (EIC) for a new installation, a new circuit or a consumer unit replacement, and a Minor Works certificate for smaller jobs.
Is fixed wire testing the same as an EICR?
Yes. Fixed wire testing is the name businesses, facilities managers and insurers often use for the periodic inspection and testing of a building's fixed electrical installation — the wiring, distribution boards, lighting, sockets and wired-in equipment, as opposed to the plug-in equipment covered by PAT testing. The result is an Electrical Installation Condition Report (EICR) on the model form in BS 7671, with every observation coded and the test results for each circuit.
Is an EICR a legal requirement for homeowners?
No. The legal duty to have the electrics inspected applies to landlords, not to people living in their own homes. It's still worth having one: IET guidance recommends an inspection every ten years for an owner-occupied home, and an EICR is a sensible check when you buy, before a renovation, or if you notice warning signs such as tripping switches, scorch marks or flickering lights.
How long does an EICR take?
A small flat usually takes a few hours; larger houses and HMOs take longer, because there are more circuits to test. The power is switched off for short periods while circuits are tested, so it's worth letting anyone at home know in advance. When we call to confirm your booking, we'll give you an idea of timing for your property.
Do I need to be there for the inspection?
No. As long as someone can let us in — a tenant, neighbour, agent or concierge — and we can reach the consumer unit, you don't need to be present. Tell us who to contact and we will arrange access with them.
What does EICR stand for?
Electrical Installation Condition Report. “Electrical installation” means the fixed wiring and everything connected to it — the consumer unit (fuse board), circuits, sockets, switches, lights and wired-in equipment. “Condition report” means it records the state of an installation that already exists, rather than certifying new work.
Can an EICR fail?
People often say a report “failed” when its overall result is unsatisfactory. On the current forms, that happens when the electrician records a C1 (danger present) or C2 (potentially dangerous) item. C3 (improvement recommended) and FI (further investigation advised) don’t make a report unsatisfactory on their own. Landlords must put C1 and C2 items right within 28 days, or sooner if the report says so.
Does an EICR check my appliances?
No. An EICR covers the fixed installation: the wiring, the consumer unit, sockets, switches, lights and wired-in equipment such as an electric shower or a cooker on its own circuit. Plug-in appliances — kettles, lamps, extension leads — are checked by PAT testing, which is a separate service.
Who has to have an EICR by law?
In England, private landlords must have the installation in each let home inspected and tested before a tenancy starts and at least every five years, and since 1 December 2025 the same rules cover social landlords. Businesses must keep their electrical systems safe under the Electricity at Work Regulations 1989; an EICR is the usual way to show they have. Homeowners aren’t required to have one.

Book your EICR today.